The Manual J form is a critical document for homeowners and contractors alike in Utah's dry climates, focusing on room-based load calculations necessary for precise HVAC sizing, including Manual D duct sizing. It encompasses detailed design information, heating and cooling equipment specifications, and requires justification for deviations from standard conditions. For those looking to ensure their home's HVAC system is efficiently and accurately sized, completing the Manual J form is a crucial step. Click the button below to start filling out your form.

Get Form

When embarking on the installation or renovation of heating, ventilation, and air conditioning (HVAC) systems in homes built within Utah's unique dry climates, a meticulous approach is required—one that the Manual J form adeptly supports. This form, a cornerstone document for residential HVAC design, streamlines the process of achieving precise load calculations on a room-by-room basis, a critical step for subsequent Manual D duct sizing estimations. Originating from the Building Services & Civil Enforcement domain of Salt Lake City, its meticulous structure requires input on numerous design conditions like altitude, inside and outside dry bulb temperatures, and even considers the impact of construction quality and the presence of fireplaces on infiltration levels. Furthermore, it delves into the detailed specifications of heating and cooling equipment, emphasizing the need for accurate matching of system capacities to calculated loads to ensure efficiency and comfort. Also, the Manual J / S Summary instructions underline the imperative of grounding these calculations and equipment selections in the actual conditions and requirements of the project, compelling designers to justify deviations when the design conditions employed diverge from standard values. This form not only underscores the importance of precision in HVAC system design but also reflects a broader commitment to energy efficiency, comfort, and sustainability in home construction and renovation projects.

Preview - Manual J Form

Building Services & Civil Enforcement slcpermits.com

801-535-6000, fax 801-535-7750

451 South State Street, Room 215

PO Box 145490

Salt Lake City, Utah 84111

Salt Lake City, Utah 84114-5490

Office only

Updated 12/2012

BLD # Received by

Date Valuation

Residential HVAC Worksheet

Manual J / S Summary

NOTE: The load calculation must be calculated on a room basis. Room loads are a mandatory requirement for making Manual D duct sizing calculations. This sheet has been developed for homs built in Utah’s dry dimares- do not use for other climate conditions.

Design Information

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Project

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Design Conditions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Htg

Clg

 

 

Altitude

 

 

ft

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outside db

 

 

°f

 

 

°f

 

Entering wb

 

 

°f

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inside db

 

 

°f

 

 

°f

 

Assume no higher than 63 °f unless there is ventilation air or significant duct leakage or heat gain

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Design TD

 

 

°f

 

 

°f

 

If design conditions used are not those listed in Table 1 / 1A Manual 3, please justify.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Infiltration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Method

 

 

 

 

 

 

 

 

Construction quality

 

 

 

 

 

 

 

 

# of fireplaces

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual J heat loss

 

 

 

 

btuh

 

Heating fan

 

 

 

 

CFM

 

Htg design TD

 

°f

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp rise range

 

 

 

 

to

 

 

°f

 

Latent gain

 

 

 

 

btuh

 

Total gain

 

 

btuh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual J sensible gain

 

 

 

btuh

 

Cooling fan

 

 

 

 

CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use SHR to determine cooling CFM / ton

 

 

 

 

 

 

 

 

 

 

 

Calculated SHR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating Equipment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Furnace manufacturer

 

 

 

 

 

 

 

Model #

 

 

 

 

 

 

 

AFUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sea level: input

 

 

 

 

 

 

btuh

 

Output

 

 

 

 

 

 

 

Altitude adjusted output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multistage

 

If yes, provide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Altitude adjusted lowest output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If “adjusted output” is greater than 1.4 times the “total heating load”, please justify

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling Equipment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC manufacturer

 

 

 

 

 

 

 

 

 

Model #

 

 

 

 

 

 

 

SEER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total capacity

 

 

 

 

 

 

btuh

 

Sensible capacity

 

 

 

btuh

 

Latent capacity

 

btuh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evaporator coil manufacturer

 

 

 

 

 

 

 

 

 

Model #

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multistage

 

TXV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Metering

 

Actual SEER rating w/ selection coil, furnace, & metering

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attach manufacturer’s data showing actual cooling capacity and actual SEER using these components

If “cooling capacity” is greater than 1.15 times the “total heating load”, please justify

Manual J / S Summary

Instructions

The load information asked for on the summary must be taken from the actual load calculation completed on the project.

Project

Identify project name, lot number- information that matches the plan submitted.

Location

The city or town must be reasonably close to actual location. Software used may not have the specific location in the database.

Outside Dry Bulb, Inside Dry Bulb

Temperature data should be from Table 1 or Table 1A of ACCA Manual J. It is understood that there may be situations where a slight adjustment to this values is necessary. For example; there may be areas in the Salt Lake Valley where the low temperature is historically lower than the airport temperature. If values are adjusted- please justify the adjustment. Provide both heating (htg) and cooling (clg) design temperatures. If inside

or outside design conditions listed are not the same values listed in Manual J, explain why the different values were used.

Entering WB

The entering wet-bulb represents the default value wet-bulb temperature across the evaporator coil. This will typically be

63 °f (75 °f dry bulb) relative humidity). A higher wb temperature will result from duct leakage, un-insulated duct or ventilation air- any condition that raises the return

air temperature. Use this wb temperature when selecting cooling condenser from manufacturer’s comprehensive data.

Design TD

TD: the temperature difference between inside and outside design temperatures.

Infiltration

Infiltration calculations are based on the Construction Quality. Version 7 of Manual ] uses Best, Average or Poor to evaluate Infiltration. Version 8AE uses Tight, Semi-Tight, Average, Semi-Loose and Loose to evaluate. Version 8 goes into very specific detail for a more accurate number. Note method used on summary. Open firebox fireplaces that draw air from inside the home must be included, even if there is a 4” ‘combustion air’ flex bring air into the fireplace. Sealed, direct vent type fireplaces should

not be counted. Methods include: Simplified

/Default Method- taken from Table 5A; Component Leakage Area Method- calculating infiltration based on individual leakage points taken from Table 5C of Manual J8; or Blower Door Method, where the actual leakage is based on a blower door test on the home.

Manual J Heat Loss

This is the whole house winter heat loss taken directly from the completed attached Load Calculation. Load must account for all factors such as loss building components as well as loss through infiltration, ventilation, and duct losses.

Heating Fan

Heating airflow typically may be lower than cooling cfm. Adjusted to insure the temperature rise across the heat exchanger falls within the range specified by the manufacturer. Software will often do this calculation and provide a correct heating cfm. See Manual S Section 2-6 - Rise (°f) = Output Capacity ÷ (1.1 x heating cfm)

Manufacturer’s Temperature Rise Range

Range taken from manufacturer’s performance data. Various manufacturers may certify ranges from 20 - 70 °f.

Manual J — Sensible Gain

The whole house summer heat gain taken directly from the completed attached Load Calculation. Load must account for all factors including gain through building components, solar gain, infiltration, ventilation and ducts. Also includes the sensible internal gains from appliances and people.

Manual 3 — Latent Gain

The gains due to moisture in the air. Large latent load are typically from moisture migration into the home from outside in humid climates. People, cooking, plants, bathing and laundry washing can all add to the latent load in a home.

Total Gain

The combined total of the sensible and latent gain. May be referred to as Total Cooling Load.

SHR- Sensible Heat Ratio

Use to determine Cooling cfm per ton. The ratio of sensible heat gain to total heat gain. SHR = Sensible Heat Gain ÷ Total Heat Gain. Recommended air flows: If SHR is below 0.80 select 350 cfm / ton; if SHR is between 0.80 & 0.85 select 400 cfm; if SHR is greater than 0.85, select 450 cfm

/ton. Note: This cfm is not the final cfm; additional adjustment may be required for Altitude. See next item- Cooling Fan.

Cooling Fan

Software used to perform the calculation will typically provide a minimum cfm based on the minimum required size of the equipment. This number may be adjusted to meet specific requirements of the home. Heating and Cooling CFM may or may not be the same. The cooling CFM should be around 450 CFM per ton of cooling in Utah’s dry climates. For higher altitudes, CFM must be adjust up as detailed in ACCA / ANSI Manual S. Mountain location should expect Cooling CFM at 500 CFM per ton and higher.

HEATING

Equipment

List specific equipment to be used. This information is not required on the Load Calculation documents, however it must be provided here to verify equipment sizing against calculated loads.

AFUE

The AFUE (Annual Fuel Utilization Efficiency) listed here will be compared to that listed on plans and on energy compliance documents (RES check or other). It must also match the equipment actually installed in the home.

Sea Level Input

The listed input on the furnace label and in manufacturers’ documentation. Input represents the total amount

of heat in the gas at sea level.

Output

The amount a heat available for discharge into the conditioned space. The input less any vent or stack losses, or heat that is carried out with the products of combustion. May be take from manufacturer’s performance data or calculated using input and furnace efficiency.

Altitude Adjusted Output

This number is the actual output that will be attained after the furnace has been adjusted for efficiency and de-rated for altitude (typically 4% for every 1000’ above sea-level, however 2% /1000’ for many 90+ efficient furnaces). Some manufacturers may have different requirements- adjustments should be made per their requirements. Calculations should be attached. Example: 80,000 input 91% efficient furnace in Salt Lake, with manufacturers’ installation instructions specifying 4% / 1000’. 80,000 x .91 x .83 = 60,424 btuh.

Multi-Stage Furnace

Multi-stage and modulating equipment is now available. When comparing to heating load calculated, use the maximum adjusted output to verify the furnace is large enough and the lowest output to insure it is not too large.

Size Justification

Example: If the Total Heating Load = 29954 btuh. A furnace with an adjusted output larger than 45,000 btuh (29954 x 1.5 = 44931) would require an explanation justifying the size.

COOLING

Equipment

List specific equipment to be used. Provide manufacturers comprehensive data for furnace, furnace blower and condenser, with capacities at design conditions highlighted.

Condenser SEER

This SEER (Seasonal Energy Efficiency Ratio) is the listed SEER for this model series, not the exact SEER with components used this system.

Total Capacity

Manufacturers base data is based on ARI Standard 210 / 240 ratings; 95 °f outdoor air temperature, 80 °f db / 67 °f wb entering evaporator. As the Design Conditions

are different than this standard, refer to manufacturers expanded ratings for capacities at actual design conditions. Total capacity is the latent and sensible capacity at design conditions

Sensible Capacity

The sensible only capacity from the manufacturer’s expanded data at design conditions.

Manual D Calculations & Summary

Project

Friction Rate Worksheet & Steps

1Manufacturer’s Blower Data

External static pressure (ESP)

IWC

CFM

 

 

 

Latent Capacity

The latent only capacity from the manufacturer’s expanded data at design conditions. NOTE: One half of the excess latent capacity may be added to the sensible capacity.

Evaporator Coil Make and Model #

List the exact model number for the evaporator coil used this system. If coil is from a different manufacturer than the condenser is used, provide data from both manufacturers verifying actual performance.

Expansion / Metering

Provide the specific metering used- orifice or TXV (thermostat expansion valve). If the manufacturer has several options, list the option used.

Actual SEER Rating

Attach manufacturers’ documentation or ARI report showing actual cooling capacity, and actual SEER using the components used this system. Indoor air handler / furnace blower must be included in this documentation. Do not use ARI (ARHI) data for actual sizing.

Size Justification

If cooling capacity is 15% greater than the calculated Cooling load explain. High latent (moisture) loads can be listed here. Special requirements particular to the customer may also be noted here.

2Device Pressure Losses

Evaporator

Supply register

.03

Other device

 

 

 

 

 

 

 

 

 

 

 

Air filter

Return grill

.03

Total device losses (DPL)

IWC

 

 

 

 

 

3Available Static Pressure (ASP)

ASP = ( ESP - DPL ) IWC

4Total Effective Length (TEL)

Supply side TEL

ft

 

Return side TEL

ft

 

 

 

 

 

Total effective length (TEL) = supply side TEL + return side TEL ft

5Friction Rate Design Value (FR)

FR = ( ( 100 x ASP ) / TEL ) IWX / 100’

Mechanical Sizing

Name of contractor / designer

Phone Fax

Address

Permit # Lot #

This friction rate (FR) calculated in Step 5 is the rate to be used with a duct calculator or a friction chart for the duct design on this project.

Attach at a minimum, a one line diagram showing the duct system with fittings, sizes, equivalent lengths through fitting and duct lengths.

Vent height (base of duct to roof exit) ft

Boiler or furnace input rating

btu

 

 

 

 

De-rated input rating (use .83)

btu

 

 

 

 

Connector rise

ft

 

 

 

 

Connector run

ft

 

 

 

 

Connector size

in

 

 

 

 

Orifice size

in

 

 

 

 

Water heater input rating

btu

 

 

 

 

De-rated input rating (.83 minimum)

btu

 

 

 

 

Connector rise

ft

 

 

 

 

Connector run

ft

 

 

 

 

Connector size

in

 

 

 

 

Orifice size

in

 

 

 

 

Total heat input of all appliances

btu

 

 

 

 

Vent size for the system

in

 

 

 

 

Combustion air size

in²

 

 

Signature

 

Boiler or furnace #2 input rating btu

De-rated input rating (use .83) btu

Connector rise ft

Connector run ft

Connector size in

Orifice size in

Water heater #2 input rating btu

De-rated input rating (.83 minimum) btu

Connector rise ft

Connector run ft

Connector size in

Orifice size in

Attach a complete gas pipe layout & sizing detail to the plan or permit application.

If a manifold is used to connect the appliances on the horizontal, it shall be the same size as the vent.

To the best of my knowledge, I certify that the information contained within this document is true, correct, and meets the requirements of the 2009 International Mechanical Code and International Fuel Gas Code.

Date

Mechanical Sizing Worksheet

 

b

Example: SLC has a 17% de-ration

How-To

 

 

factor. On a 100,000 Btu furnace you

Materials needed to fill out this form are the

 

 

multiply 100,000 x .83 = 83,000 Btu’s

 

c

On the vent sizing this becomes

International fuel gas Code and the Questar

 

Recommended Good Practices Book.

 

 

the fan min. The fan max is the

VENT SIZING

 

 

listed input rate example fan

 

 

min = 83 and fan max = 100

1

Vent height is measured from the

 

d

The Btu to ft³ conversion number for

 

draft diverter or appliance vent

 

 

SLC is 890 and the specific gravity of

 

outlet to the top of the vent cap.

 

 

the gas is .60. Divide the new input

2

Connector rise is the height of the vent

 

 

rating by 890, 83,000 = 93.258 ft³. 890

 

 

 

 

connector from the appliance outlet

 

e

Take the ft³ of input and divide it by the

 

to the center of the tee in the vent at

 

 

number of burners on the appliance,

 

the point of connection to the vent.

 

 

this will give you the ft³ / burner. Then

3

Connector run is the horizontal distance

 

 

use the orifice tables in the Questar

 

 

handbook to determine the orifice size.

 

from the appliance vent outlet to the vent.

 

 

 

 

 

Example if you have 4 burners: 93.258

 

 

 

 

4

Go to the International Fuel Gas

 

 

ft³ / 4 burners = 23.315 ft³ / 1 burner.

 

Code Chapter 5. Sizing is done to

 

 

Match as close as possible to the

 

the appropriate gamma table .

 

 

Orifice table in the handbook. In this

5

The gamma tables are in Btu and not ft³

 

 

sample the orifice size would be (49)

2

Use the International Fuel Gas Code and the

DE-RATING

 

International Mechanical Code to complete

 

 

 

1

See Questar handbook for a step-by-step

 

the vent sizing and the combustion air

 

sizing. See Chapter 5 IFC for the rules and

 

formula and the required conversion

 

 

 

the tables to fill out this portion of the form.

 

numbers. To complete this form:

 

 

 

ICBO also has available a commentary on

 

 

 

 

a Input is de-rated at 4% per

 

the mechanical code that contains a step-

 

1000’ in elevation.

 

by-step examples of how to size the vents.

3The International Mechanical Code commentary also contains examples to size the gas pipe. You must show the pipe lengths, the Btus and the volume of each appliance and show the size of each length of pipe. All tables necessary to size gas pipe are also contained in the International Fuel Gas Code, and in the Questar handbook.

4For Salt Lake City use:

a890 Btu per ft³

bA multiplier of .83

cSpecific gravity of .60

dCombustion air is computed at 1 in² per 3,000 Btu of input of all fuel burning appliances in the room. One duct upper 12” of the room.

EQuestar gas has a training program available to all persons and contractors.

Document Specs

Fact Name Detail
Purpose of Manual J Form Residential HVAC Worksheet for Manual J / S Summary, designed for homes in Utah's dry climates.
Office Information Building Services & Civil Enforcement, Salt Lake City, Utah; contact number 801-535-6000.
Climate Consideration Specifically developed for Utah's dry climates and is not suitable for other climate conditions.
Load Calculation Requirement Load calculation must be calculated on a room basis for Manual D duct sizing calculations.
Design Conditions Includes both heating and cooling design temperatures, with adjustments justified against Manual J criteria.
Infiltration Method Evaluation Assesses construction quality and includes number of fireplaces; methods include Simplified/Default, Component Leakage Area, and Blower Door Method.
Heating and Cooling Equipment Requirements Equipment sizing must align with calculated loads; includes AFUE for heating and SEER for cooling equipment.
Manual D Calculations & Summary Includes a Project Friction Rate Worksheet & Steps for duct design tailored to the specific project.

Instructions on Writing Manual J

Filling out the Manual J form is an essential process for those engaged in residential HVAC design, ensuring that heating and cooling systems are properly sized according to the specific needs of a home. This document requires detailed information about the project and an accurate load calculation to make informed decisions regarding HVAC equipment. The steps provided here are designed to guide you through the completion of the Manual J form, ensuring each section is comprehensively filled out to reflect the true requirements of the building in question.

  1. Start by indicating the Project Name and Lot Number, aligning this information with the plan submitted for consistency.
  2. Specify the Location of the project by listing the city or town, ensuring it closely matches the actual location of the construction.
  3. Input the Outside Dry Bulb and Inside Dry Bulb temperatures using data from Table 1 or Table 1A of ACCA Manual J, adjusting these values if necessary with appropriate justification.
  4. For the Entering WB (Wet Bulb) temperature, use the default value unless there are reasons (such as duct leakage or un-insulated duct) to use a higher temperature, providing justifications for adjustments.
  5. Detail the Design TD (Temperature Difference), which is the difference between inside and outside design temperatures.
  6. Under Infiltration, select the calculation method based on construction quality or other standards applicable and include details of any open fireplaces.
  7. Record the Manual J Heat Loss and Heat Gain, ensuring these values are taken directly from the completed load calculation for the whole house.
  8. Adjust the Heating and Cooling CFM (Cubic Feet per Minute) as necessary, based on the temperature rise range and SHF (Sensible Heat Factor) calculated.
  9. List the Heating Equipment, including furnace manufacturer, model, AFUE (Annual Fuel Utilization Efficiency), and both sea level and altitude-adjusted output.
  10. For Cooling Equipment, provide details of the AC manufacturer, model, SEER (Seasonal Energy Efficiency Ratio), total capacity, and sensible and latent capacities. Attach manufacturer’s data to validate the choices.
  11. Ensure to attach any additional justification needed for size selection of both heating and cooling equipment if the chosen sizes differ significantly from the calculated loads.

Completing this form with accurate and detailed information is critical for determining the appropriate HVAC system size for a residential building. This process ensures efficient heating and cooling performance tailored to the specific characteristics of the home, accounting for all factors such as climate conditions, house construction, and the residents’ comfort needs.

Understanding Manual J

What is a Manual J form?

A Manual J form is a detailed document used to calculate the heating and cooling loads of a residential property. This calculation is crucial for determining the size of the HVAC (Heating, Ventilation, and Air Conditioning) system needed for a home, ensuring it is neither under nor over-sized. The calculations take into account various factors such as the home's construction, orientation, window types, and local climate conditions.

Why is a Manual J calculation important?

Performing a Manual J calculation is essential for ensuring comfort, efficiency, and energy savings in a home. Properly sized HVAC equipment runs more efficiently, lasts longer, and ensures consistent temperatures throughout the home. Over-sized equipment can lead to humidity control problems, temperature variations, and increased energy costs, while under-sized equipment might not adequately heat or cool the home.

Who should perform a Manual J calculation?

A Manual J calculation should ideally be performed by a qualified HVAC professional or energy auditor who is trained in the correct use of the ACCA (Air Conditioning Contractors of America) Manual J methodology. These professionals have the expertise to accurately assess the home’s features and enter the correct information into the Manual J software or perform manual calculations.

What information is required for a Manual J calculation?

The calculation requires detailed information about the home, including insulation levels, window type and sizes, floor plan, geographical orientation, local climate data, and more. The construction quality and any special characteristics, such as high ceilings or extensive glass areas, also need to be considered.

Can I do a Manual J calculation myself?

While it is possible for homeowners to attempt a Manual J calculation themselves, especially with the availability of various software options, it is generally recommended to have it done professionally. The calculations can be complex, and accurate input data is crucial for reliable results.

What happens after a Manual J calculation?

After a Manual J calculation is performed, the next steps involve selecting HVAC equipment that fits the calculated load requirements. Manual S, another guide from the ACCA, is used for this equipment selection process. Following the proper selection, a Manual D calculation is done for proper ductwork design.

How often should a Manual J calculation be performed?

A Manual J calculation should be carried out whenever a new HVAC system is being installed, when making significant modifications to an existing system, or after making major changes to the home’s structure or insulation. This ensures that the HVAC system is always appropriately sized for the home.

Is a Manual J calculation required by law?

Whether a Manual J calculation is legally required can vary by location. However, many local building codes and regulations now require a Manual J calculation for new installations or major renovations to ensure energy efficiency and comfort standards are met.

What are the consequences of not performing a Manual J calculation?

Skipping a Manual J calculation can lead to improperly sized HVAC systems, resulting in less comfort, higher utility bills, increased wear and tear on the equipment, and potentially, a shorter lifespan for the heating and cooling system.

Can a Manual J calculation save money?

Yes, a Manual J calculation can lead to significant savings. By ensuring that the HVAC system is neither too large nor too small, it operates more efficiently, uses less energy, and reduces wear and tear. This can decrease both upfront costs by avoiding over-sized equipment and long-term expenses through lower utility bills.

Common mistakes

When people fill out the Manual J form, a common mistake is not accurately calculating room-by-room loads. The form requires detailed calculations for each room to accurately size HVAC systems. Skipping this step or making ballpark estimates can lead to improperly sized HVAC systems, resulting in inefficiency and discomfort.

Another frequent error is choosing incorrect design conditions. The form specifies using design conditions from Table 1 or Table 1A of ACCA Manual J, yet often users adjust these values without proper justification. Misjudging the outdoor and indoor design temperatures affects the heating and cooling load calculations, potentially leading to an oversized or undersized system.

Incorrectly estimating infiltration rates is yet another issue. The form delineates various methodologies to account for air leakage in and out of the building, which significantly impacts heating and cooling needs. Users commonly select the wrong infiltration rate for their building's construction quality or misuse the simplified/default method without considering their specific situation, leading to inaccurate results.

Many also fail in providing accurate heating and cooling CFM (Cubic Feet per Minute). The form instructs to adjust the CFM based on the Sensible Heat Ratio (SHR) and altitude adjustments, particularly in Utah’s dry climates. Ignoring these adjustments can result in the HVAC system not moving the correct volume of air for optimal heating and cooling, affecting the system's efficiency and the occupants' comfort.

Last but not least, a critical mistake is incorrect equipment selection. The Manual J form includes sections for specifying heating and cooling equipment based on calculated loads. However, selecting a furnace or air conditioner without correctly matching its output capacity to the building’s calculated need often leads to significant inefficiency. Oversized equipment cycles more frequently, leading to increased wear and higher operational costs, while undersized equipment may not adequately heat or cool the space.

Documents used along the form

Alongside the Manual J form, professionals in the HVAC and construction fields frequently utilize additional documents to ensure comprehensive and accurate planning and compliance with local codes. These documents complement the Manual J form, providing a complete picture of an HVAC system’s requirements and proving compliance with efficiency and safety standards.

  • Manual S - Residential Equipment Selection: This document complements the Manual J load calculation and aids in selecting the appropriate heating and cooling equipment based on the calculated loads. It ensures the equipment size meets the home's specific needs, enhancing comfort and efficiency.
  • Manual D - Residential Duct Systems: Used for designing the ductwork in a residential HVAC system, Manual D ensures proper sizing and layout of the duct system. It helps in minimizing energy loss and optimizing airflow, critical factors for achieving efficient and effective heating and cooling.
  • REScheck: A software application used to demonstrate compliance with residential energy codes, specifically for insulation and window and door specifications. It simplifies the process of ensuring that new constructions or renovations meet the requirements of the International Energy Conservation Code (IECC) or state-specific codes.
  • ACCA Manual T - Air Distribution Basics for Residential and Small Commercial Buildings: Focuses on the correct selection and placement of air distribution components, such as grilles, registers, and diffusers, to ensure comfortable and efficient air movement throughout the living spaces.
  • HVAC Contractor Proposal/Contract: A detailed proposal or contract from the HVAC contractor outlines the scope of work, equipment to be installed, cost estimates, and payment schedules. This document provides clarity and agreement between the homeowner and contractor, ensuring both parties understand the project's expectations and deliverables.

Using these documents in conjunction with the Manual J form ensures a holistic approach to HVAC system planning and execution. They not only assist in the technical aspects of system design and equipment selection but also in adhering to legal and code requirements, resulting in efficient, effective, and compliant installations.

Similar forms

The Energy Audit Report, similar to the Manual J form, assesses energy usage and efficiency within homes or buildings. Both documents are pivotal in identifying how systems within a structure perform under varying conditions. Energy Audit Reports focus on a broader range of factors including insulation, window efficiency, and overall energy consumption. This expansive approach complements the specific HVAC system analysis provided by the Manual J, together painting a comprehensive picture of a building's energy performance.

Construction Permit Applications share a common purpose with the Manual J form in that both are necessary steps in the planning and approval process for residential construction or renovation projects. The Manual J, with its detailed HVAC load calculations, often forms part of the documentation required for a construction permit. Both documents ensure compliance with local building codes and standards, promoting safe and efficient design and construction practices.

The REScheck Report is designed to demonstrate compliance with residential energy codes, paralleling the specific HVAC focus of the Manual J form. It calculates and verifies a home's energy performance, ensuring it meets or exceeds the International Energy Conservation Code (IECC). While the Manual J focuses on HVAC load calculations, REScheck encompasses a broader assessment, including insulation, window, and door efficiency, linking them together in the overall pursuit of energy code compliance.

Manual D forms, which concentrate on duct system design and sizing, are a natural extension of the Manual J calculations. After determining the heating and cooling loads with Manual J, Manual D is used to ensure that the ductwork can effectively distribute air throughout the building. Both documents are critical for optimizing HVAC system performance, ensuring it's not only properly sized but also that it delivers comfort efficiently to all areas of the home.

The HVAC Equipment Selection, or Manual S, operates in tandem with the load calculations provided by Manual J. Manual S uses the results from Manual J to help select appropriate heating and cooling equipment, taking into account factors such as size, efficiency, and climate condition suitability. Together, they ensure that the HVAC system is not only accurately sized but also meets the specific efficiency and comfort needs of the structure.

Building Insulation and Air Sealing Forms, while not HVAC-specific, relate closely to the Manual J form in their mutual aim to enhance home energy efficiency. These documents evaluate and plan for the proper insulation and sealing of a building, directly impacting the heating and cooling load calculations conducted in Manual J by altering the rate of heat transfer and air infiltration within a structure. Therefore, they are complementary in the pursuit of energy-efficient building design.

The Home Energy Rating System (HERS) Report, like the Manual J, evaluates a home's energy performance but from a holistic perspective. It considers all aspects of energy usage, including HVAC, to assign a rating that reflects the home's overall efficiency. The Manual J's detailed analysis of HVAC load is a critical component of the broader energy efficiency picture painted by the HERS Report.

ASHRAE Load Calculations are technical documents that, like Manual J, focus on determining the heating and cooling loads of buildings but cater to a wider variety of structures, including commercial and institutional buildings. Both document types utilize similar principles and methodologies to ensure HVAC systems are properly sized to meet the unique demands of each building, highlighting their essential role in efficient building design.

Heat Loss/Gain Calculations, often a component of more comprehensive energy assessments or specific HVAC design tasks, share the Manual J form's core objective: to accurately quantify the heating and cooling needs of a space. These calculations inform decisions regarding HVAC system sizing, insulation needs, and other critical factors influencing energy consumption and comfort levels within a building.

The Mechanical Plan Review Checklist is a tool used by building departments to ensure that HVAC installations comply with local codes and regulations, including those calculations and selections justified by Manual J and Manual S forms. This checklist ensures that all aspects of the HVAC system design, from equipment selection to ductwork layout, are scrutinized for compliance and efficiency, tying the detailed analysis back to regulatory standards.

Dos and Don'ts

When filling out the Manual J form, it’s important to follow guidelines carefully to ensure accurate completion. Here are some do’s and don’ts to consider:

  • Do make sure to calculate load information based on actual calculations completed for the project.
  • Do match project identification information accurately with the plans submitted.
  • Do use Outside Dry Bulb and Inside Dry Bulb temperature data from Table 1 or 1A of ACCA Manual J, adjusting only as necessary and with justification.
  • Do accurately account for all heat loss and gain factors, including building components, infiltration, ventilation, and duct losses.
  • Do specify and justify any deviations from design conditions listed in Manual J when selecting heating and cooling equipment.
  • Do select equipment based on calculated loads and ensure the selection meets manufacturer’s recommendations and design conditions.
  • Do attach manufacturer’s data showing actual cooling capacity and actual SEER for selected cooling equipment, along with a justification if the capacity is greater than recommended.
  • Don’t use the Manual J form for climates other than Utah’s dry climates without adjustments for climate differences.
  • Don’t guess or estimate values; use accurate load calculations for each room.
  • Don’t omit details about open fireboxes or specific ventilation equipment that can affect load calculations.
  • Don’t fail to justify any adjustments made to the default values provided in Manual J.
  • Don’t overlook the need to adjust heating and cooling CFM for altitude, especially in Utah’s varied terrain.
  • Don’t forget to include manufacturer’s performance data for heating and cooling equipment.
  • Don’t neglect to justify the size of the selected equipment if it deviates from the calculated load requirements.

Misconceptions

When it comes to the Manual J form for residential HVAC work, misconceptions can make the process seem more complicated than it actually is. Let's clear up some of the common misunderstandings:

  • It's only for use in Utah: Despite the form being developed with Utah's dry climates in mind, the principles of Manual J calculations are applicable across different climate conditions, with proper adjustments for local weather data.

  • It's too complex for non-experts: While the Manual J form involves detailed calculations, the process is streamlined through software and training, making it accessible to HVAC professionals and not solely the domain of engineers.

  • Room-by-room calculations aren't necessary: Contrary to belief, room-by-room load calculations are a mandatory requirement. They ensure accurate sizing of HVAC equipment and ductwork for individual spaces.

  • Manual J is the only requirement: Completing a Manual J calculation is just the start. For a comprehensive HVAC design, Manual S (for equipment selection) and Manual D (for ductwork design) are also essential.

  • Software is always accurate: While software greatly aids in performing Manual J calculations, its accuracy is contingent upon correct data input. Garbage in, garbage out—therefore, professional judgment is crucial.

  • All construction is treated equally: The form distinguishes between different construction qualities and types, affecting infiltration and ventilation calculations. Understanding the nuances of construction plays a significant role in the calculation process.

  • Design conditions are standardized: Design conditions can vary significantly based on geographic location and local climate data. The Manual J form allows for adjustments to these conditions, emphasizing the need for localized knowledge.

  • Fireplaces don't impact calculations: Open firebox fireplaces, which draw indoor air, indeed affect HVAC load calculations and must be accounted for, unlike sealed, direct vent fireplaces which do not.

  • Any HVAC equipment will do, as long as it's new: Selecting the correct size and type of HVAC equipment is critical and must be based on the completed Manual J calculation, as per Manual S requirements. Oversized or undersized equipment can lead to inefficiency and discomfort.

Understanding these misconceptions helps demystify the Manual J form, making it clear that while it requires careful attention to detail, it is a manageable task with the correct approach and knowledge.

Key takeaways

Filling out and using a Manual J form is essential for accurately determining the heating and cooling needs of a home, ensuring that the HVAC system is properly sized for efficiency and comfort. Here are key takeaways users should consider:

  • The Manual J form requires detailed calculations based on room-by-room analysis to accurately determine HVAC load requirements, underscoring the necessity for precise measurements and considerations of each space within a home.
  • It is specifically tailored for homes in Utah's dry climates, indicating the importance of considering local climate conditions when conducting load calculations to ensure accuracy and efficiency.
  • Design conditions, such as outside and inside dry bulb temperatures, must align with those listed in Table 1 or 1A of ACCA Manual J unless adjustments are justified, highlighting the need for adherence to established benchmarks while allowing for flexibility based on real-world conditions.
  • Infiltration calculations, which impact heating and cooling loads, vary based on construction quality and the presence of features such as fireplaces, necessitating a thorough evaluation of a home's construction and features for accurate load determination.
  • The form includes detailed sections for both heating and cooling equipment, requiring the submission of technical specifications and justifications for system sizing, ensuring that equipment is appropriately matched to the home's needs.
  • Adjustments for altitude are necessary for accurately determining HVAC equipment output, particularly important in mountainous regions like Utah, where altitude significantly affects equipment performance.
  • Manual J calculations are instrumental in selecting HVAC equipment, as they help verify that the chosen furnace or air conditioner is neither too big nor too small for the calculated load, promoting efficient operation and avoiding unnecessary energy consumption.
  • The form incorporates considerations for both sensible and latent gains, emphasizing the need to account for all sources of heat gain and loss within a home to ensure the HVAC system can maintain comfortable conditions year-round.
  • Properly filled-out Manual J forms play a critical role in complying with local building codes and regulations, underscoring the legal and practical importance of accurate load calculation and equipment sizing in residential HVAC design.

In summary, the Manual J form is a critical tool for ensuring that HVAC systems are accurately sized according to the specific needs of a home. By taking into account a wide range of factors including climate conditions, home construction, and system specifics, this form helps to optimize comfort and efficiency while meeting regulatory requirements.